
NimaPrime™ Conditioning Reagent
NimaPrime™ Conditioning Reagent is used to prime the polymer pump of Genetic Anayzers, as well as wash the polymer pump and channels when switching between polymer types or performing routine maintenance. The RFID labeled pouche is compatible with all Data Analysis Software versions of 3500 Series and SeqStudio™ Flex. NimaPrime™ Conditioning Reagent is a drop-in replacement for Applied Biosystems™ Conditioning Reagent for 3500/SeqStudio™ Flex.
Applied Biosystems and SeqStudio are trademarks of Thermo Fisher Scientific.
ReCAP™ Capillary Array Regeneration Kits for 3130 and 3730

Capillary array as a carrier for polymers (e.g. POP™ and NimaPOP™ separation media) is critical for peak separation in Sanger Sequencing and Fragment Analysis. At the end of the array life, it will not generate well-separated peaks. ReCAP™ Capillary Array Regeneration Kit for 3130 Series Genetic Analyzers has been designed for in-line cleaning of the capillary array, aimed at rejuvenating failing arrays to like new, maintaining optimal performance and improve operational life span. ReCAP™ Capillary Array Regeneration Kit contains 4 different buffer solutions, to be applied sequentially to the pump blocks and capillaries via the instrument’s inbuilt Water Wash Wizard protocol.

ReCAP™ Capillary Array Regeneration Kit for 3730 Series Genetic Analyzers is used to perform a complete rejuvenation and revitalization of old and failing capillary arrays. Particularly those arrays that start to lose resolution, or show smears or tails in the electropherogram. Additionally, it cleans the pump blocks of the machine, preventing or eliminating yellow or red haze. Regeneration extends the lifespan of the array, maintaining optimal performance, avoiding the cost of unnecessary early array replacement. ReCAP™ requires no disassembling or reassembling of the array. There is no need for spectral and spatial calibration after array cleaning.
NimaPrime™ Conditioning Reagent and ReCAP™
NimaPrime™ Conditioning Reagent for 3500/SeqStudio™ Flex
ReCAP™ Capillary Regeneration Kit for 3500 Series w/ NimaPOP™-4
ReCAP™ Capillary Regeneration Kit for 3500 Series w/ NimaPOP™-6
ReCAP™ Capillary Regeneration Kit for 3500 Series w/ NimaPOP™-7
ReCAP™ Capillary Regeneration Kit for 3730 Series
ReCAP™ Capillary Regeneration Kit for 3130 Series
NimaPOP™ Polymers and Running Buffer for Fragment Analysis
NimaPOP™ comprises a range of polymers for performing Fragment Analysis of DNA using Capillary Electrophoresis (CE), combined with NimaPOP™ running buffer.
In combination with Seq-DI™ Formamide and DNA Size Standards the ideal solution for separating DNA fragments of a known size range at a desired resolution and run time, for results and data you can trust.
